s500_e

flox[on] S500



The measurement of the flox[on] mass flow controller is temperature and pressure compensated with a very high control accuracy in the lower and upper flow ranges. The adjustment control of the mass flow controller uses a pressure compensated proportional valve of the most recent design, which makes it unsusceptible to pressure fluctuations in the in- and outlet. The flox[on] mass flow controller is equipped with a high-performance micro-controller. This guarantees an unusually quick and dynamic regulation.

Application
The flox[on] mass flow controller was especially developed for use in the heavy industry.
it is suitable for all noncorrosive gases like, air, nitrogen, argon or hydrogen.

Measurement Principle
The measurement is based on the principle of thermal anemometry. The measuring cell is located in the bypass. A gas flow of max. ca. 1 Nl min.-1 undergoes a constant energy feed by means of an electric heating element. The thermal feedback is converted to an electrical signal and then linearized through a calibration curve to give the effective flow rate.

Data operation flox[on] S500

Maximum flowNlmin-11650
Minimum flowNlmin-12
Maximum operating pressurebar16
Regualtion ratio1 : 500
Accuracy± 3%
Step response (10% - 90%)s1 t0 5
Operating temperature°Cfrom -10 to +60

flox[on] S500 Electrical Equipment

Connection voltageV DC24 ± 15 %
Capacity max.W30
Connection analogmAThread ½“ BSP
Signal Set/Real4 - 20
Bypass SignalV DC24

dimensions flox[on] S500

dimensions flox[on] S500


 

3_05

flox[on] S500

 

 

 

Application:

For noncorrosive gases like air, nitrogen, argon or hydrogen


Materials:

Housing and flange connector - aluminium

Valve and sinter filter - brass


Any further questions?

If you have any additional questions, please do not hesitate to contact us.


Datasheet

get the complete datasheet for flox[on] B here


get datasheet flox[on] S500